UL-100 with 4-20 mA
Current Output |
|
|
Function: Continuously senses liquid level in tanks and outputs a 4-20 mA current proportional to the level. The monitoring is done without contacting the liquid. The current output can be connected to a programmable controller, computer, remote display or relay module. Also, displays liquid level in tank. Use: Any liquids or slurries, including: Chemicals, Acids, Caustics, Oils, Fuels, Gasoline, Lubricants, Adhesives, Creams, Lotions, Viscous Fluids, Pharmaceuticals, Foods, and Beverages, Open Channel Flowmeter, Flow computer. Features: Range of use: |
![]() ![]() UL-100 Level Transmitter |
|
Advantages of our transmitter:
|
|
| SPECIFICATIONS | |
|
Ranges = Tank Height: UL-100... 0-15 feet, 4.5 meters. UL-200... 0-40 feet, 12 meters. Outputs: 8-digit LCD readout of level, std. 4-20 mA into 600 Ohm, std. 1-5 VDC or 2-10 VDC, opt. RS232C, distance up to 2000 ft., opt. Remote digital display, opt. Accuracy: ±0.3% of span Repeat ability: ±0.1% span Resolution: 0.002 ft. max Power: 115VAC ±10%, 50/60Hz, 5 VA, std. 220VAC ±10% 50/60Hz, opt. + 12 to + 24 VDC, 0.3 Amp., opt. Enclosure: NEMA 4X polycarbonate 7" x 9" x 4", std. Warranty: 18 months from the date of shipment. |
Standard Sensors (Transducers): Standard with UL-100: #7508, all PVC housing, 9" blind zone, 10° beam Standard with UL-200: #4012A, all PVC housing, 18" blind zone, 12° beam Temp. - 40°F to 170°F, both above. For suggested transducer mounting, Click Here. Optional Sensors:
Sensor Cable: |
Automated Sonix Corporation |
|