US flag Source of Level Sensor, Tank Indicator, Level Controls. US flag
HOME

Sonix-1000

UC-4000

UL-1000

LP-10

UL-100

Sonix-11

Ultrasonic Sensors (Transducers):

The sensors (transducers) are sealed air and water tight and are not affected by condensation, humidity, fumes, splashing liquid or hose down. All are intrinsically safe. We also offer an explosion-proof transducer #4012BS/CSA, approved for all Class I environments.
A broad variety of transducers, used with our ultrasonic controllers, offers the best selection to suit any typical industrial application. The transducers are mounted above the highest monitored level, allowing a non-contact measurement. They are connected to the controller using a standard RG62/U coaxial cable, require no external power and, depending on model, may be remotely installed up to 800 feet from the control electronics. Supplied with 25 ft. of cable, additional cable lengths may be ordered installed to avoid field splicing.
The transducers are heavy duty, hermetically sealed and available in PVC, Teflon®, 316 stainless steel, CPVC, or Kynar® housing. The ultrasonic signal travels perpendicular from the transducer radiating face as a narrow, cone shaped beam. When the monitored object is within this cone, is more-less perpendicular to the signal and within the transducer operating range, it will reflect the echo back and be recognized. Since the transducer face vibrates rapidly during transmission, it is naturally self cleaning and therefore, build-up of material on the transducer face is not expected.
     
Selection Suggestion:
Select transducers by its range (for tanks less than 15 feet high, or more than 15 feet high) and the transducer material for best corrosion resistance.



7508

Ultrasonic Transducer 4012B, level sensor
   
Transducer 4012BS, level sensor. 


2006



Transducer 2310
2310
       

MODEL:
        

7508:   All PVC housing, for tanks to 15 feet high, temperature -40° to +190°F, 9 inches blind zone (see note below ), 8 degrees beam, 75KHz frequency. Fits standard 2-inch opening.  Standard with Sonix-1000, UL-100, Sonix-11. See Dimensions.          

7508-Teflon:   All Teflon housing,  for tanks to 15 feet  high, temperature -40° to +220°F, 12 inches blind zone (see note below ), 8 degrees beam, 75KHz frequency. Fits 1-3/4 inch opening.  Optional with Sonix-1000, UC-4000, UL-100, Sonix-11.           

4012B:   PVC housing. For tanks to 35 feet high, temperature -40° to +190°F, 18 inches blind zone (see note below ), 9 degrees beam, 40KHz frequency. Fits standard 3-inch opening.  Standard with Sonix-2000, UL-200. See Dimensions.       

4012A:   Same as 4012B except for tanks to 50 feet high.

4012CPVC:
Same as 4012B except all CPVC housing.

4012-Teflon:   All Teflon housing. For tanks to 35 feet high, temperature -40° to +220°F, 18 inches blind zone (see note below ), 9 degrees beam, 40KHz frequency. Fits standard 3-inch opening.  Optional with Sonix-2000, UC-4000, UL-200.          
  
4012BS:   All 316 stainless steel housing. For tanks to 35 feet high, temperature -40° to +220°F, 18 inches blind zone (see note ), 9 degrees beam, 40KHz frequency. Fits standard 3-inch opening.  Optional with Sonix-2000, UC-4000, UL-200. See Dimensions.

4012BS/CSA:   EXPLOSION-PROOF, CSA approved for all Class I, Groups A, B, C & D hazardous environments. All 316 stainless steel housing, same specifications as 4012BS.

2006:   PVC housing with Buna-N radiating face. For tanks to 4 feet high, temperature -40° to +190°F, 5 inches blind zone (see note below ), 5 degrees beam, 200KHz frequency. Fits standard 2-inch opening. Optional with Sonix-1000, UC-4000, UL-100, Sonix-11. See Dimensions. 

2006-Teflon:   Same as 2006 except all Teflon housing. Fits 1-1/2 inch opening.

2007-Teflon:   Same as 2006 except all Teflon housing. Fits 1 inch opening.

2310:   PVC housing with Buna-N radiating face. For tanks to 80 feet high, temperature -40° to +190°F, 22 inches blind zone (see note below ), 9 degrees beam, 23KHz frequency. Fits 4-1/2 inch opening.  Standard with Sonix-3000. See Dimensions.

3-A Sanitary Transducers:
Available in PVC, Teflon, Kynar and 316 stainless steel.

Suggested Transducer Mounting:
  
                  
Flange Mounts:
  We can supply transducers with optional PVC flange mounted. The flanges are ANSI standard, 150 lbs.
     
FA:Flange- bottom mount      FB:   Flange- top mount
                
(Note: Blind zone is the shortest distance to recognize the monitored surface. The transducer has to be installed at least this distance above the highest liquid level)

Note that all transducers have a mounting nipple with a 3/4" NPT thread (model 2310 has 1" NPT) for convenient mounting into any coupling or cavity thread of the same size.

Transducer Dimensions:

   7508 and 2006:
75082006draw..jpg (4086 bytes)         
                      
  

4012B and 4012A:

4012BS and 4012BS/CSA:   
4012BSdraw..jpg (5248 bytes)

   2310:              