OPERATION:

The transmitter commences a regular operation as soon as the power is applied. Except for the 4 mA and 20 mA switch calibration, there is no set up required. During stationery or slowly changing liquid level, the transmission cycle repeats continuously about seven times per second. The transmitter self-adjusts its damping during turbulence for best results. Also, it continuously adjusts the signal beam width for narrowest possible.
When a rapidly changing level is detected, the transmitter will automatically increase the frequency of transmission and decrease the output damping for a faster response.


Aside from calculating the current output proportional to the monitored level, the internal microprocessor performs the following:
* self-diagnostics and announces each received valid echo using a red LED light.
* signals any possible operating problems, such as loss of echo, level beyond the calibrated range, etc. using internal LED.
* upon an echo loss, the output will switch to a high, approximately 22 mA current.
* temperature compensating calculations.


SPECIFICATIONS:

Range (Tank Height):
Sonix-50 ..... 0-15 feet, 4.5 meters
Sonix-60 ..... 0-40 feet, 12 meters
Output:
4-20 mA into 600 Ohm, sourcing
Optional Outputs:
  1-5 VDC, 2-10 VDC (multiple orders)
  RS232C, distance up to 2000 feet
  Internal modem for telephone
   connection
  Linearized output proportional to
   horizontal tanks volume.
Accuracy:    +/-0.25% of span (in air)
Repeatability:   +/-0.1% of span
Resolution:         0.04 inch
Power:
12 to 30 VDC, 0.1 Amp.
Green LED Power-On indication
Wiring:
2 power wires + current output wire
Enclosure:
PVC cartridge, NEMA-4X type,
Length:  8 inches
Diameter: Sonix-50 = 1-1/4"
                Sonix-60 = 2-1/2" 
Beam:
Sonix-50: 8-degrees, 12" blind zone
Sonix-60: 10-degrees, 18" blind zone
Automatic adjustment of beam width and gain
 


Operating Temperature:

-10° F to 190° F
Optional Signal Face:

TeflonŽ, KynarŽ, 316 stainless steel, CPVC.
 
Other Options:

*external board with up to six set points, each with
   SPDT relay, 5 Amp., 250 VAC  contact rating.
* If you have several Sonix-50 with RS232C outputs, we can combine all these individual RS232C's to provide you with only one RS23C output for easy connection to computer or PLC. Ask about Data Concentrator.
* Internal modem with RJ11
    telephone jack
* Remote loop-powered displaysfor your panel mounting, choice of  LED or LCD, 3-1/5 or 4-1/2 digits. Adjustable to your engineering units.     Display enclosures available.

  Tank level indicator, liquid level monitor.   fuel level gauge, tank level  gauge.
 
 

Warranty:
12 months from the date of shipment under normal use. The warranty carries no liability, expressed or implied, beyond the obligation to repair or replace the part under warranty.

Return