Sonix-1000, 2000 and 3000: |
|
|
Monitors liquids level or volume in one, two, three, four, five, six or seven tanks. All tanks are scanned automatically and level or volume of each tank is displayed in sequence.
optional modem. |
![]() |
| NEW GENERATION: The Sonix series is a new generation of level controller. It has features not available anywhere, incorporating entirely different and original philosophy that we believe will set a standard for the future.
THE ULTRASONIC PRINCIPLE: |
|
| OPERATION: Large, alphanumeric LCD display automatically shows level of each tank in inches, feet or meters and displays volume in US gallons or liters, as selected by the user. The results are announced in clear English (no codes are needed). The volume display includes also horizontal tanks, no strapping tables, no programming is required. All measurements, including alarm set points and current output, are checked and updated several times per second. The controller performs self-diagnostics during regular operation to maintain the most reliable performance. The controller continuously monitors all tanks at the same time by automatically alternating the transmission and the processing between the transducers. If two or more tanks are monitored, the display will automatically alternate in about 3 second intervals between each tank. However, each of the tanks will be monitored several times per second. For easy orientation, the display will show TANK 1, TANK 2, TANK 3, etc. title with any displayed data. Each tank can have its own dedicated current output flowing continuously and its own set point relay outputs. The outputs (4-20 mA current, alarm relays), however, appear as if each were coming from an individual unit. |
![]()
TRANSDUCERS: See the
TRANSDUCERS here for details. |
| SPECIFICATIONS | |
|
RANGE: To simplify ordering, SONIX series are divided to models, depending on the standard transducers range = TANK HEIGHT: SONIX 1000 ...... 0-15 feet
tank height ± 0.25% of span REPEAT ABILITY: ± 0.1% of span POWER: 115 VAC ±10%, 50/60Hz, 10VA, std. 220 VAC ±10%, 50/60Hz, 5VA, opt. +12 VDC ±10%, 0.5 Amp., opt. +24 VDC ±10%, 0.4 Amp., opt. ENCLOSURE: SENSORS: |
All transducers (except 316SS) are available in Teflon® or Kynar® housing. Mounting flanges available, 3" to 8" PVC See TRANSDUCERS for more options. For SUGGESTED SENSOR MOUNTING, Click Here. SENSOR CABLE: RG62/U coaxial cable, 30 ft. std. length, longer cable installed when ordered. STANDARD OUTPUTS: * 20-character LCD readout of level and volume. * RS232C computer connectible output, only 2 wires needed. OPTIONAL OUTPUTS: * One, two or three programmable set point relays per each tank. * 4 to 20 mA current output into 500 Ohms per each tank, programmable span - no calibration. * Duplicate remote display, distance up to 2000 feet.MODEM: Optional internal or external, Hayes compatible. INTERNET, ETHERNET Access: Optional Internet and Ethernet 'plug and play' connection using internal IE-1 controller, IEEE 1451.2 interface, 10Base-T Ethernet interface, embedded Web server and RS232C. Not available for single unit. Contact us for details. DUPLICATE REMOTE DISPLAY: Duplicate 20-character alphanumeric display can be located as far as 2000 feet from the controller. The connection to controller is via any 3-wire cable. This display duplicates the controller display. Mount in your panel. Warranty: 18 months from the date of shipment under normal use. Call 941-964-1361 with any question. Ask for detailed Product Bulletin. |
UC-4000
UL-1000
LP-10
UL-100
Sonix-50
Sonix-40
Sonix-11
Transducers