Non-Contact Level Sensor with Pump
and Valve Control !
LP-10 and
LP-20:
¨ Controls directly pump or solenoid valve, ON-OFF operation.
¨ Includes Relay Latch for Pump-In and
Pump-Out.
¨
Includes High
and Low Alarm Relays.
¨ No Field Calibration Required.
¨ Easy Installation, No Maintenance.
¨ Reliable Operation, No
Moving Parts.
¨ Not Affected by Fumes and
Condensation
¨ Automatic Temperature
Compensation.
¨
Displays Level or Volume for Vertical
and Horizontal Tanks.
LP-10 and LP-20 level sensors are used
to continuously monitor (sense) and indicate
level or volume of liquids such as chemicals, water, fuel, diesel
and heating oils, lubricants, etc. in horizontal as well as vertical tanks.
Based on the level in tank, LP sensor turns ON
or OFF pump or solenoid valve. The user is only required to set
the High and Low liquid levels to select either Pump-In or Pump-Out
operation. The internal latching relay contact is configured to turn power
to pump/valve on or off.
The High and Low alarm relays can be used for alarm in case
pump fails. Or, they could be wired for second pump control.
This product is designed
to replace or upgrade from older mechanical gauges and float controls.
Field calibration is not required. The basic difference between
LP-10 and
LP-20 models is the maximum range of measurement (tank height or
tank diameter). LP-10 can monitor
tanks to 15 feet high. LP-20 is for
any taller tanks.
The sensing is non-contact; transducer
is mounted above the highest level in tank and thus will not touch the
fluid. The monitor transmits an ultrasonic signal directed toward the
monitored surface and measures the time to receive the reflected echo. The
time is then converted to depth of liquid in tank. This enables an accurate
measurement over the entire range. Microprocessor then performs the
calculations and displays level or volume in tank on highly visible LCD
display. Based on the level, microprocessor then determines whether to turn
pump or valve ON or OFF.
INITIAL SETUP:
Is required only once, anytime, prior or after installation. It
can be done on your desk and even without transducer being connected. The
user would set pump/valve ON and OFF level (to control pump or solenoid
valve) and vertical distance between transducer and tank bottom (needed for
digital readout).
All this is a very simple task, done by jogging push button switches until
the correct level is shown in display. We will be happy to do that for you
if you provide us with the levels information. These initial setup
data are stored in the microprocessor’s non-volatile memory and will remain
there forever, or until the user changes it for some reason. Power loss, no
matter how long, will not erase the data.
________________________________________________________
SPECIFICATIONS:
RANGE:
LP-10: for tanks up to 15 ft.
tall.
LP-20:
all
larger (taller) tanks.
READOUT:
Feet
or Inches (standard), meters (optional)
U.S. gallons and Liters (optional)
ACCURACY:
+/-
0.25% of span
REPEATABILITY:
+/- 0.15% of span
POWER:
115
VAC +/- 15%, 60 Hz, 6VA (std.)
220 VAC +/- 15%, 50 Hz (opt.)
12 VDC or 24VDC, 0.25 Amp. (opt.)
ENCLOSURE:
NEMA-4X Outdoor, polycarbonate with clear view cover, 9” x 7” x 4” (std.)
Operating Temp. 20°
F to 150°
F.
STANDARD
TRANSDUCER:
LP-10: #7508, PVC housing,9” blind zone,
2” diameter.
LP-20: #4012A,
PVC housing, 15” blind zone,
3” diameter.
Operating Temperature –20°F
to + 190°F,
both.
(Both above transducers also available in optional Teflon housing).
For
suggested transducer mounting,
Click Here.
OPTIONAL TRANSDUCERS:
#4012BS, 316 stainless steel housing.
#4012BS/CSA, 316 SS, Explosion-proof, approved by CSA for all Class
I, Groups A, B, C & D. Both range to 30 feet, blind zone 18”. 3” diameter
both.
#4012-Teflon, Teflon housing, range to
40 ft., 3" dia.
#2006, PVC, Teflon or 316 stainless steel, ranges to 6 ft., blind
zone 5” to 8”.
Plus variety of other 316 SS and Teflon transducers for ranges to 8 ft.
TRANSDUCER CABLE:
RG62/U coaxial, 30 ft. furnished (std.). Longer cables installed on request.
Or, you
may purchase the additional cable locally.
|
TYPICAL
APPLICATION:
 |

INSTALLING TRANSDUCER:
Remove the blind flange or cap from the opening on top of the
tank. Drill a hole in the center of flange or cap. Tap the hole with ¾-inch
NPT female thread. Thread the transducer into this hole and place the
transducer-flange assembly back on the tank opening. The transducer cable
should be placed in a conduit, to protect it from elements.
For
suggested transducer mounting,
Click Here.
INSTALLING the CONTROL ENCLOSURE:
Mount the enclosure on a wall, post, skid, etc. The enclosure can be
installed several hundred feet away from the tank. Attach the transducer
cable to the clearly marked screw terminals inside. Connect 120 VAC, single
phase wires to the AC screw terminals inside. Connect wires to control pump
or valve as per wiring diagram in the Instruction Manual, furnished with the
product. Turn power On, and that is all.
LP-10 and LP-20 are designed for
durability in harsh industrial environments. Installed properly, they
will operate trouble free for a long time,
requiring no maintenance. Breakdowns are minimized by a
conservative design and many years of field-proven test experience. The
sensors are immune to acoustic and electrical noise, turbulence or liquid
splashing on the transducers. They are not affected by radio, radar or
microwave transmission.
The transducers are industrial grade,
hermetically sealed, non-corrosive in a PVC housing (std.), 316 stainless
steel, Teflon® or Kynar®. All are intrinsically safe with one model in 316
stainless steel housing approved for Class I, Groups A, B, C & D hazardous
environments. The transducer is connected to the controller via a coaxial
cable and can be remotely mounted up to several hundred feet, depending on
model. Please, see the Transducers page for details.
__________________________________________________________
SPECIFICATIONS- Continued:
For
suggested transducer mounting,
Click Here.
OUTPUT:
8-digit LCD display in feet or inches. (optional display in US
gallons, liters, meters, etc.)
RELAYS:
Latching
Relay, 10
Amp, 250 VAC contacts rating, for Pump-In and Pump-Out.
High Alarm Relay,
120VAC, 50 watts.
Low Alarm Relay,
120VAC, 50 watts.
OPTIONAL
OUTPUTS:
4-20 mA
programmable current output.
1-5 VDC programmable output.
WARRANTY:
18 months from the day of shipment under normal use. The warranty carries no
liability, expressed or implied, beyond the obligation to repair or replace
the part under warranty.
LP-10/20 INPUT WIRING TERMINAL:

|